DAPNIA-02-482 |
---|
A fully automated test bench for the measurement of the field distribution in RFQ and other resonant cavity. |
F. Simoens, F. Ballester, A. France, J. Gaiffier, A. Sinanna |
As part of the RF studies of the resonant cavities of the “IPHI” accelerator project (“Injector of Proton High Intensity”), a fully computer controlled bench for the field distribution measurement has been developed. Based on the perturbation method, the acquisition of the s21 transmission coefficient phase shift is synchronized with the displacement of a bead. A systematic study of the noise and uncertainties has led to a clearly enhanced signal over noise. The measured raw data are then converted to a quantity proportional to the electromagnetic field magnitude. Specifically for the RFQ tuning study, different transverse section positions where to guide the bead have been tested on our RFQ cold model. |